Products / TESA / Gauge Block Calibration Instruments

TESA · Bench & Electronic

Gauge Block Calibration Instruments

Compare TESA UPC and UPD gauge-block comparator arrangements. Configure the measuring instrument, references, temperature measurement, handling equipment and software around the calibration procedure.

Compare options ↓

TESA UPC
TESA UPCRepresentative configuration · Accessories vary by model
Measurement applications

What can you measure?

Measurement application

Gauge-block length deviation

Determine the difference between a gauge block and a suitable reference using a defined comparator procedure.

Measurement application

Variation in measured length

Where required by the procedure, acquire readings at defined face positions to evaluate variation in length. Specify the contact pattern and reference method.

Measurement application

Temperature for length evaluation

Measure the relevant temperatures with a suitable arrangement when assessing thermal effects or applying the specified length corrections.

Compare within this category

Models and measurement options

Family / option Configuration Selection notes
UPC Comparative gauge-block measurement Select reference blocks, procedure and measurement uncertainty.
UPD Comparative and direct measurement capability Review the complete configuration for the intended method.
TESA UPT Temperature measurement for UPC/UPD Specify sensors and the required thermal monitoring arrangement.
TESA UP software Gauge-block calibration workflow software Confirm instrument connection, calculations and report requirements.
References and handling accessories Reference sets, guides, pliers and thermal protection Select accessories for the block sizes and calibration sequence.

This comparison describes product families and configurations. Confirm the exact range, permissible error, accessories and documentation with the selected part number. Display resolution alone does not state measurement accuracy.

Specify the complete setup

What to consider before choosing

Calibration scope

List nominal sizes, materials, grade and required measurement uncertainty. Define the calibration procedure.

Environment and temperature

Specify room conditions, stabilisation, temperature monitoring and the approach to thermal effects.

Reference and workflow

Identify reference blocks, contact sequence, handling tools, software and report contents.

Choosing your instrument

Frequently asked questions

Should I compare UPC or UPD?

TESA lists UPC for comparative measurement and UPD for comparative and direct measurement. Select against the calibration method and required uncertainty.

Which gauge-block sizes should I specify?

List the shortest, longest and intermediate nominal lengths, together with material and grade. Review the measuring configuration, reference blocks and handling accessories for that range.

Are the reference blocks and temperature equipment included?

Confirm the supply scope explicitly. TESA lists reference sets, UPT temperature equipment and handling accessories as separate items.

What should I provide for a proposal?

Send the gauge-block size range, materials and grades, calibration method, uncertainty target, room conditions, reference inventory and required reports.

Start with your component

Discuss TESA gauge block calibration instruments

Gauge-block sizes, materials/grades, calibration procedure, uncertainty target, references, temperature control and reports.

India availability, supplied accessories and lead time are confirmed with the quotation.

    Manufacturer references: TESA product category. Product photos show representative configurations. .